Traduciendo...
HEAT SINK TEMPERATURE Ax
Axis Heat Sink Overtemperature
Kuka · KR C2 Robot Controller
¿Qué significa HEAT SINK TEMPERATURE Ax ?
An overtemperature condition has been detected on the heat sink of the servo drive module for the specified axis (Ax). This indicates inadequate cooling or excessive load on the axis.
Causas comunes
- Ambient temperature in the cabinet is too high.
- Insufficient cooling for the drive's heat sink (blocked vents, fan failure).
- Drive operating at peak load for extended periods.
- Oversized motor or drive operating inefficiently.
- Faulty temperature sensor on the heat sink (P6-01).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the cabinet cooling circuit and fans for proper operation and airflow.
- 2
Reduce the load on the affected axis by decreasing the Override (OVR) setting in the robot program.
- 3
Reduce the velocity for the affected axis using the `$VEL_AXIS` parameter.
- 4
Reduce the acceleration for the affected axis using the `$ACC_AXIS` parameter.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kuka KR C2 Robot Controller