OVERCURRENT Ax
Axis Overcurrent
Kuka · KR C2 Robot Controller
¿Qué significa OVERCURRENT Ax ?
This fault indicates an overcurrent condition on the specified axis (Ax). Possible causes include overloading of the axis or an I²t overload. A defective KSD module could also be the root cause.
Causas comunes
- Mechanical overload on the motor exceeding its rated current (P3-01).
- Incorrect motor tuning parameters, leading to excessive current draw.
- Short circuit in the motor windings or motor cable.
- Drive unit commanded to produce torque beyond its capability.
- Encoder feedback error causing incorrect current control (P4-xx).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Reduce the load on the affected axis by decreasing the Override (OVR) setting in the robot program.
- 2
Reduce the acceleration for the affected axis using the `$ACC_AXIS` parameter.
- 3
If the issue persists, exchange the KSD module for the affected axis.