invalid optional Slave Configuration
Invalid Optional Slave Configuration
Kuka · KR C4 DeviceNet
¿Qué significa invalid optional Slave Configuration ?
The 'ecat_DNM_Gateway.xml' file, which contains the optional slave configuration, is faulty. This prevents the correct setup of optional DeviceNet slave devices and causes a DeviceNet master configuration error (Message 4429).
Causas comunes
- The configuration for an optional slave device attached to the Gateway is invalid.
- Optional slave device parameters do not match expectations.
- Communication failure with the optional slave.
- Incorrect setup of optional slave profiles or features.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Correct the errors within the 'ecat_DNM_Gateway.xml' file.
- 2
Reconfigure the bus after correcting the file.
Datos técnicos verificados. Última actualización: March 2026