26047

Power supply failure, KPP/KSP (axis)

Kuka · KR C4 extended

¿Qué significa 26047 ?

The supply voltage to the KPP or KSP module for a specific axis has fallen below 300 V. This indicates an insufficient power supply, potentially causing erratic operation or complete shutdown.

Causas comunes

  • Power lead is damaged or disconnected.
  • KPP cabling fault.
  • Supply voltage dropped below 300V.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the power lead for damage and proper connection.

  2. 2

    Check KPP cabling for damage and correct connections.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.