Traduciendo...
26050

Fault in brake resistor, KPP/KSP (axis)

Kuka · KR C4 extended

¿Qué significa 26050 ?

The KPP module has detected an error in the ballast circuit, which typically includes the brake resistor. This indicates an issue with the energy dissipation components, potentially leading to overvoltage conditions if braking energy cannot be properly absorbed.

Causas comunes

  • Ballast resistor fault.
  • Cabling between KPP and ballast resistor is damaged or improperly connected.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the ballast resistor for damage or overheating.

  2. 2

    Check cabling between the KPP and the ballast resistor for damage and correct connections.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.

Ver todos los códigos en este manual (35)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas