PROFIBUS Master Configuration Error
Kuka · KR C4 PROFIBUS
¿Qué significa 4429 ?
The PROFIBUS master experienced an error related to its configuration. The specific cause is detailed in the accompanying 'Cause of error' message, indicating an issue with the setup or parameters of the PROFIBUS master.
Causas comunes
- The PROFIBUS master configuration file contains incorrect network parameters.
- A required slave device is missing from the master's configuration table.
- Duplicate slave addresses assigned within the PROFIBUS network.
- Mismatched GSD files between the master and slave devices.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that all connected PROFIBUS devices are listed in the master's configuration file.
- 2
Ensure each PROFIBUS slave has a unique station address.
- 3
Confirm that the GSD file version for each slave matches the one used in the master configuration.
- 4
Check the PROFIBUS network topology against the configuration file.