invalid Gateway Error-Byte Config
Invalid Gateway Error-Byte Configuration
Kuka · KR C4 PROFIBUS
¿Qué significa invalid Gateway Error-Byte Config ?
The configuration of the error status bytes for the devices does not match the overall bus configuration. This suggests a mismatch in how error conditions are reported or interpreted.
Causas comunes
- Error-byte configuration in the gateway is invalid or not supported.
- Incorrect bitmask or value set for error reporting in the gateway.
- Firmware mismatch between gateway and configuration tool.
- Attempting to configure error reporting beyond device capabilities.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the bus configuration in WorkVisual for consistency in error byte settings and correct if necessary.
- 2
Reconfigure the bus after correcting the configuration.