1422

Variable Value Invalid

Kuka · KSS 8.3 System Software

¿Qué significa 1422 ?

This message indicates that a variable has an invalid value during program execution. For example, if a program line like `myPos = $POS_INT` is executed, it may trigger this message if the variable `$POS_INT` holds an invalid state. The error can be suppressed by `ON_ERROR_PROCEED` in the preceding line, allowing custom error handling via `$ERR.NUMBER`.

Causas comunes

  • A variable used in the NC program has an invalid value or is not initialized.
  • Macro variable assignment error or usage of an undefined variable.
  • The value assigned to a program variable falls outside its permissible range.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Examine the program logic in the line triggering the error (e.g., line 5 `myPos = $POS_INT`) and preceding lines to understand why the variable value is invalid.

  2. 2

    Verify that all variables used in assignments, calculations, or function calls have appropriate data types and are initialized with valid values.

  3. 3

    If `ON_ERROR_PROCEED` is active, ensure the subsequent `SWITCH ($ERR.NUMBER)` block explicitly handles `CASE 1422` with a robust fault service function.

  4. 4

    If the error occurs within an interrupt routine, investigate the context of the interrupt and the data available to the program at that time.