LaserStill- NotReady

Laser still not ready or not assigned

Kuka · LaserTech 3.1

¿Qué significa LaserStill- NotReady ?

The laser program cannot be started because the laser is not in a ready state or has not been assigned for use. Possible causes include the laser being off, undergoing a reset, or being in manual mode.

Causas comunes

  • Laser system is not ready for operation.
  • Laser has not been assigned to the current process.
  • Laser system internal diagnostic failure.
  • Laser ready signal is absent.
  • Laser is in an error state preventing readiness.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure the laser system is switched on and fully powered.

  2. 2

    Confirm the laser is not currently being reset.

  3. 3

    Verify the laser is not in manual mode (refer to 'LsrInManual-Mode' resolution).