Traduciendo...
RobotStandStill
Standstill monitoring: Laser was switched off because robot welded for too long at the same position
Kuka · LaserTech 3.1
¿Qué significa RobotStandStill ?
The laser has been automatically deactivated because the robot remained stationary, welding at the same position for a duration exceeding the configured standstill monitoring time (LSR_Stop_InspectionTime).
Causas comunes
- Standstill monitoring detected robot welding at the same position for too long.
- Robot movement has been stopped due to excessive dwell time.
- Robot position monitoring triggered a halt.
- Standstill timer exceeded for robot motion.
- To prevent overheating or damage, robot motion was halted.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
If prolonged welding at a fixed position is intentionally required, increase the value of the LSR_Stop_InspectionTime parameter in the configuration.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kuka LaserTech 3.1