Traduciendo...
SikContactOpen
Laser safety circuit is still open: Ensure laser safety before the robot program is resumed
Kuka · LaserTech 3.1
¿Qué significa SikContactOpen ?
The laser safety circuit remains open, preventing safe laser operation. This could be due to an actual open safety interlock or a mismatch between the light path settings in the laser and the requested light path configuration.
Causas comunes
- Laser safety interlock circuit is open.
- Ensuring laser safety is required before resuming robot program.
- Safety contact for laser is not made.
- Laser safety door or cover is not closed.
- One or more safety sensors for the laser are not active.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect all components of the laser safety circuit (e.g., safety doors, light barriers, emergency stops) to ensure they are closed and functional.
- 2
Verify that the light path settings configured in the laser system match the light path requested by the robot program.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kuka LaserTech 3.1