11001

Connection to device terminated

Kuka · ProfiNet Controller/Device 3.1

¿Qué significa 11001 ?

The PROFINET connection to the specified device ({Name}) has been terminated. This fault indicates an interruption in the device's power supply or a physical break in the network connection, leading to a complete loss of communication.

Causas comunes

  • The connection to the device has been unexpectedly terminated.
  • Network cable disconnected or faulty.
  • Device powered off or rebooted unexpectedly.
  • Communication protocol error.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the power supply to the PROFINET device {Name} by checking voltage at its power terminals.

  2. 2

    Inspect the network cable connected to device {Name} for any physical damage, loose connections, or disconnections at both ends.

  3. 3

    Check network switch port status connected to device {Name} to confirm link activity.

Ver todos los códigos en este manual (13)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Kuka ProfiNet Controller/Device 3.1