Traduciendo...
082

Sd2

Lenze · 9300 Series

¿Qué significa 082 ?

A resolver error has occurred at terminal X7, typically indicating an interrupted resolver cable. This prevents accurate position feedback.

Causas comunes

  • Break or open circuit in one or more conductors of the resolver feedback cable connected to terminal X7.
  • Poor or corroded connection at the resolver connector, terminal X7 on the drive, or within the resolver itself.
  • Damaged resolver sensor (e.g., mechanical impact, contamination, internal short) providing incorrect or no feedback signals.
  • Incorrect resolver wiring to terminal X7 (e.g., swapped sine/cosine signals, incorrect shield connection).
  • Excessive electrical noise or interference on the resolver cable causing signal corruption.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Power down and lockout the drive. Disconnect the resolver cable from terminal X7 on the drive and at the resolver end.

  2. 2

    2. Using a multimeter, check continuity of each individual wire within the resolver cable from end to end.

  3. 3

    3. Measure the resistance of the resolver windings at the resolver connector (e.g., between reference and sine, reference and cosine). Refer to the resolver datasheet for expected values.

  4. 4

    4. Inspect terminal X7 on the drive and the resolver connector for bent pins, corrosion, or loose connections.

  5. 5

    5. Ensure the resolver cable shield is properly connected to the drive's designated ground terminal and the motor frame.

Ver todos los códigos en este manual (145)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas