Traduciendo...
157

Parameter set mode is absolute instead of relative.

Lenze · 9300 Series

¿Qué significa 157 ?

An absolute parameter set (C1311) was performed or is active during relative positioning (position mode C1210). This mismatch in positioning modes prevents correct operation.

Causas comunes

  • The positioning mode parameter (e.g., C1210) is configured for relative positioning, but a motion command or parameter set (e.g., C1311) expecting an absolute position reference was issued.
  • A program sequence in the master controller or internal drive logic incorrectly switches between absolute and relative motion commands without updating the drive's active mode.
  • Incorrect parameter value downloaded for the positioning mode (C1210) not matching the application's intended operation.
  • Communication error or corrupted data causing the drive to misinterpret the intended motion mode from the master controller.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Verify the current positioning mode (Parameter C1210) and ensure it matches the application's requirements (0 = relative, 1 = absolute).

  2. 2

    2. Review the motion control program (PLC or master controller) for any instances where an absolute parameter set (e.g., C1311) is called while the drive is configured for relative mode.

  3. 3

    3. Adjust the positioning mode parameter (C1210) to match the type of positioning commands being sent, or modify the motion program accordingly.

  4. 4

    4. Perform a drive parameter backup and restore, or re-download the correct parameter set to ensure C1210 is accurately applied.

  5. 5

    5. Monitor the drive's status words (e.g., P5-06 for mode bits) to confirm the drive's active positioning mode prior to the fault.

Ver todos los códigos en este manual (145)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas