Traduciendo...
P19

Input values at X9 are limited

Lenze · 9300 Series

¿Qué significa P19 ?

The function block DFIN is limiting the input values at X9, which causes a loss of increments. This suggests an issue with the digital frequency connection or a mismatch in master/slave settings, affecting precise control.

Causas comunes

  • Digital frequency input (DFIN) parameters (e.g., P1-60 to P1-63) are configured to limit the input frequency or pulse count received at X9.
  • The frequency signal applied to X9 exceeds the maximum permissible input frequency defined by DFIN scaling parameters.
  • Mismatch between the master encoder output frequency and the slave device's DFIN input scaling, causing saturation or clipping.
  • Noise or signal integrity issues on the digital frequency input lines at X9, leading to misinterpretation of high frequency pulses.
  • Incorrectly set filter parameters (e.g., P1-64) for the DFIN input at X9, causing signal attenuation at higher frequencies.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review parameters P1-60 (DFIN scaling) and P1-61 (DFIN maximum input frequency) to ensure they match the expected input signal range.

  2. 2

    Using an oscilloscope, measure the actual frequency and amplitude of the signal applied to X9 to ensure it's within expected limits.

  3. 3

    Adjust the master device's output frequency or the slave device's DFIN scaling parameters (P1-60 to P1-63) to prevent exceeding limits.

  4. 4

    Verify the integrity of the cabling to X9 for proper shielding and termination to minimize noise, especially for high-frequency signals.

  5. 5

    Temporarily disable or adjust any active filters (e.g., P1-64) on the DFIN input to see if they are causing unintended signal limitation.

  6. 6

    Check for any internal function block logic (e.g., via diagnostic software) that might be imposing additional limits on the DFIN value after scaling.

Ver todos los códigos en este manual (145)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas