Traduciendo...
25218

User-defined fault 2

Lenze · i550 Protec Drive

¿Qué significa 25218 ?

This fault indicates that the 'Activate fault 2' function has been triggered within the flexible I/O configuration. The activation specifically occurred via the input trigger selected in parameter 0x2631:044 (P400.44). This fault type typically results in the motor being brought to a standstill.

Causas comunes

  • An external safety device or process sensor connected to the input (Parameter 0x2) activated, triggering 'Activate fault 2'.
  • Incorrect wiring or a loose connection to the digital input specified for 'Activate fault 2' (Parameter 0x2).
  • Persistent or transient signal on the configured input due to electrical interference or faulty cabling.
  • Misconfiguration of the input trigger in Parameter 0x2, inadvertently selecting a constantly active signal.
  • Failure of the digital input circuit on the drive's I/O board associated with 'Activate fault 2'.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Determine the specific digital input terminal linked to 'Activate fault 2' by checking Parameter 0x2.

  2. 2

    Monitor the voltage state of the identified digital input terminal (e.g., X1.2) using an oscilloscope to detect unexpected transitions.

  3. 3

    Check the operational status of the external sensor or switch connected to the input for proper functioning and physical integrity.

  4. 4

    Verify the programming of Parameter 0x2 to ensure the input is configured correctly (e.g., positive or negative logic).

  5. 5

    Temporarily disable the 'Activate fault 2' monitoring function in Parameter 0x2 to confirm if the fault originates from the input signal path.

Ver todos los códigos en este manual (52)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas