1A31H

Command Generation Axis Positioning Address Out of Range

Mitsubishi Electric · MELSEC iQ-R Motion Controller

¿Qué significa 1A31H ?

This minor error indicates that the indirect setting for the positioning address for the command generation axis is outside the acceptable range. The valid range is 0 to (value of [Pr.346] Command generation axis length per cycle - 1). If the address is outside this range, the positioning control will not initiate.

Causas comunes

  • Positioning address for indirect setting is configured outside the valid range of 0 to ([Pr.346] Command generation axis length per cycle - 1).

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the value of parameter [Pr.346] Command generation axis length per cycle.

  2. 2

    Adjust the indirect positioning address to be within the range of 0 to ([Pr.346] Command generation axis length per cycle - 1).

Ver todos los códigos en este manual (19)
Datos técnicos verificados. Última actualización: March 2026