Multiple CPU System Initial Communication Error
Mitsubishi Electric · MELSEC System Q/L Series
¿Qué significa 7002 ?
This fault signifies a failure in the initial communication process between CPU modules in a multiple CPU system. It is triggered by a lack of response from a target CPU module or the presence of an incompatible CPU module within the system. The error occurs at power ON or reset, causing the multiple CPU system to stop.
Causas comunes
- No response received from the target CPU module during initial communication within the multiple CPU system.
- A CPU module incompatible with the multiple CPU system was mounted.
- Potential hardware fault in any of the CPU modules if the error persists after other corrective actions.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Reset the CPU module and attempt to transition it to RUN mode again.
- 2
Remove any CPU module identified as incompatible with the multiple CPU system from the main base unit.
- 3
Replace any CPU module incompatible with the multiple CPU system with a compatible one.
- 4
Verify all communication cabling between CPU modules for proper connection and integrity.