Traduciendo...
E7

Indoor Unit Communication Receive Error

Mitsubishi Electric · PAR-21MAA MA Remote Controller

¿Qué significa E7 ?

The indoor unit has detected an error in receiving communication signals from the outdoor unit. This indicates a problem with the data transmission path from the outdoor unit or the indoor unit's receiving circuit, leading to a loss of control and coordination.

Causas comunes

  • Indoor unit fails to receive valid data packets from the outdoor unit.
  • Communication cable issue (open, short, noise) between indoor and outdoor units.
  • Faulty communication receiver chip on the indoor unit PCB.
  • Outdoor unit not transmitting data correctly or at all.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the indoor/outdoor connecting wire terminations match the wiring diagram for correct connection.

  2. 2

    Inspect the indoor/outdoor connecting wire and power supply for signs of electrical noise interference that could disrupt signal reception.

  3. 3

    Cycle power to the unit (turn off, then on again) to re-check for the error.

Ver todos los códigos en este manual (26)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Mitsubishi Electric PAR-21MAA MA Remote Controller