Indoor/Outdoor Miswiring (Converse) or Disconnection

Mitsubishi Electric · PUZ-HA30/36NHA4 Outdoor Unit

¿Qué significa Eb ?

The connecting wiring between the indoor and outdoor units has been miswired (converse wiring) or a disconnection has occurred. This critical fault prevents proper communication and control between the units, leading to system malfunction.

Causas comunes

  • Reversed wiring connections between indoor and outdoor units.
  • Disconnection in the communication wiring.
  • Faulty wiring harness or connectors.
  • Incorrect cable type used for communication.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the connecting wiring between the indoor and outdoor units for correct phase and signal line connections.

  2. 2

    Verify the continuity of the connecting wire, specifically checking for any breaks or disconnections in the S3 line.

  3. 3

    Inspect the indoor controller board for any visible defects or damage.

  4. 4

    Inspect the outdoor controller circuit board for any visible defects or damage.