Traduciendo...
E14
Master/Slave System Configuration Error
Mitsubishi Electric · R410A Systems
¿Qué significa E14 ?
This error indicates incorrect DIP switch (SWS) settings on the indoor unit PCB for master/slave configuration, or an open circuit in the control wiring between master and slave units. This prevents proper communication and coordinated operation.
Causas comunes
- Incorrect designation of master and slave units in a multi-system.
- Missing or incorrect master/slave configuration parameters.
- Communication failure between units in a master/slave setup.
- System requires a specific master unit which is absent or faulty.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the DIP switch (SWS) settings on the indoor unit PCB of both master and slave units are configured according to the system's master/slave documentation.
- 2
Check continuity and secure connections of the control wiring between the master and slave indoor units using a multimeter.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Mitsubishi Electric R410A Systems