04AE0000 hex

Regeneration Tr Error

Omron · NJ/NX-series Machine Automation Controller

¿Qué significa 04AE0000 hex ?

The Servo Drive regeneration drive Tr is faulty. This indicates a malfunction in the transistor (Tr) responsible for handling regenerative energy within the Servo Drive, which could impair braking performance.

Causas comunes

  • The Servo Drive regeneration drive Tr is faulty.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify external braking resistor connections to the servo drive terminals for secure and correct wiring.

  2. 2

    Measure the resistance of the external braking resistor with a multimeter to confirm it matches the specified value.

  3. 3

    Check Servo Drive parameters for correct configuration of the external braking resistor's resistance and power rating.

  4. 4

    Inspect the braking resistor for signs of physical damage, discoloration, or overheating, indicating potential overload.