04B10000 hex

Node Address Setting Error

Omron · NJ/NX-series Machine Automation Controller

¿Qué significa 04B10000 hex ?

The node address that was read from the rotary switches was not between 00 and 99. This indicates an invalid network address configuration for the Servo Drive, preventing proper network communication.

Causas comunes

  • The Servo Drive failed.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the physical setting of the rotary switches on the Servo Drive, confirming the node address is configured within the valid range of 00 to 99.

  2. 2

    Inspect the rotary switches for any physical damage, signs of corrosion, or debris that might impede proper contact, and gently cycle them through a few positions.

  3. 3

    Perform a controlled power cycle of the Servo Drive to force a re-initialization and re-read of the node address from the rotary switches.

  4. 4

    Consult the system network configuration documentation and the Omron NJ/NX-series Controller project to confirm the intended and valid node address assignment for the specific Servo Drive.