Dummy Sensors Setting Error
Omron · NJ/NX-series Machine Automation Controller
¿Qué significa 34F80000 ?
An excessive number of dummy units are configured, which prevents real sensors from being assigned necessary logical unit numbers. This configuration error impacts the system's ability to properly recognize and utilize actual sensors.
Causas comunes
- Configuration includes too many Dummy Units, exhausting available logical unit numbers for actual sensors
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the current I/O configuration in Sysmac Studio for the Omron NJ/NX controller, focusing on the definition and assignment of physical and dummy I/O units.
- 2
Identify all configured dummy units within the Sysmac Studio project and compare their quantity against the actual physical I/O modules and sensors installed.
- 3
Check the logical unit number assignments for all real sensors and physical I/O modules within Sysmac Studio to identify conflicts or unassigned necessary logical numbers.
- 4
Inspect the I/O table and memory allocation within the controller's project settings to confirm sufficient logical unit number space for all required real sensors.