CNC Multi-execution Disabled
Omron · NJ/NY-series NC Integrated Controller
¿Qué significa 56040000 hex ?
This minor fault occurs when multiple CNC functions that cannot run concurrently are attempted for the same target, such as a CNC coordinate system. It is detected at instruction execution within the CNC Function Module, affecting CNC common or a specific CNC coordinate system. The relevant instruction will not execute, and the CNC coordinate system will stop immediately if it is moving.
Causas comunes
- Multiple CNC instructions, specified as non-simultaneously executable, were triggered for the same CNC coordinate system.
- The `CNC_LoadProgramFile` instruction was executed while any CNC coordinate system was in an `Executing` or `Hold` state.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review the CNC program to identify instances where multiple instructions are executed simultaneously targeting the same CNC coordinate system.
- 2
Consult the instruction specifications to determine which instructions cannot be executed concurrently.
- 3
Modify the program logic to ensure that instructions identified as non-concurrent are not executed at the same time for the same CNC coordinate system.