Traduciendo...
A295.11

No END(001) Error

Omron · SYSMAC CJ2 CPU Unit

¿Qué significa A295.11 ?

This flag indicates that the mandatory END(001) instruction is missing from the PLC program. Every executable PLC program segment must properly terminate with an END(001) instruction to define its logical end. Absence of this instruction prevents proper program execution.

Causas comunes

  • The END(001) instruction was accidentally omitted or deleted from the main program block.
  • Program corruption preventing the CPU from recognizing the END instruction.
  • Improper program structure or multiple program segments without proper termination.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure that the END(001) instruction is explicitly present at the end of the main program block in the ladder logic.

  2. 2

    Recompile and download the entire program to the CPU to verify its structural integrity.

  3. 3

    Check for any unused or incomplete program segments that might interfere with the main program's termination.

Ver todos los códigos en este manual (27)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas