Traduciendo...
DC Under Voltage
DC Under Voltage
Otis · 400 Elevator
¿Qué significa DC Under Voltage ?
Indicates that the voltage from the power supply was under 20VDC for more than 30 seconds. This signifies an insufficient power supply or an excessive load condition on the DC bus, potentially affecting multiple components.
Causas comunes
- Shorts in the vender wiring or components.
- Crimped or smashed wires in the vender.
- Defective power supply unit.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check for shorts in the vender.
- 2
Check for crimped or smashed wires in the vender.
- 3
Replace any damaged cables.
- 4
If no damaged cables can be found and repaired, replace the power supply.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Otis 400 Elevator