1LS / 2LS Check Negative
Otis · GAA21750AK3 Service Tool
¿Qué significa >LS-FAULT ! ?
This blinking event message indicates that the safety check for Limit Switch 1 (1LS) or Limit Switch 2 (2LS) has failed, blocking elevator operation. This fault implies a critical issue with the limit switch integrity or its monitoring circuit on the OTIS 2000 Controllers MCS120/MCS220.
Causas comunes
- Malfunction of Limit Switch 1 (1LS) or Limit Switch 2 (2LS).
- Incorrect wiring or poor connection to 1LS or 2LS.
- Mechanical damage or misalignment of the limit switches.
- Fault in the LCB_II control system's monitoring of limit switches.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect Limit Switch 1 (1LS) and Limit Switch 2 (2LS) for physical damage, obstruction, or misalignment.
- 2
Verify electrical connections to both 1LS and 2LS for continuity and proper termination.
- 3
Measure the voltage across the 1LS and 2LS terminals in both actuated and non-actuated states, comparing with expected values.
- 4
If accessible, manually actuate each limit switch to confirm its switching action.