Traduciendo...
CFF
INCORRECT CONFIG.
Schindler · Altivar 312 Drive
¿Qué significa CFF ?
This fault indicates that the current drive configuration is inconsistent, possibly due to the addition or removal of an option card. An inconsistent configuration can prevent proper drive operation.
Causas comunes
- The drive's internal configuration data is inconsistent.
- An option card has been added to or removed from the drive without a configuration update.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Return the drive to its factory settings.
- 2
Retrieve and load a previously backed-up configuration, if it is valid. Refer to the [Restore config.] (FCS) parameter (page 46).
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Schindler Altivar 312 Drive