COM.E

Communication error

Schindler · Easy Altivar ATV310 Drive

¿Qué significa COM.E ?

This communication error indicates a 50 ms timeout, appearing after 220 retry attempts. It signifies a problem with the communication link between the drive and the remote display terminal, preventing proper data exchange.

Causas comunes

  • A 50 ms communication timeout error between the drive and the display terminal.
  • Loose or faulty wiring connections for the communication cable.
  • Electromagnetic interference affecting the communication line.
  • Incompatible communication settings between the display terminal and the drive.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the physical communication wiring between the display terminal and the drive for secure connections and proper termination.

  2. 2

    Inspect the communication cable for any signs of damage, wear, or incorrect routing that could lead to interference.

  3. 3

    Verify that the communication settings (e.g., protocol, address, baud rate) on both the display terminal and the drive are correctly configured and match.

  4. 4

    Ensure that both the drive and the display terminal are properly powered and that power supplies are stable.