trAP

Trap Code (Internal Software Error)

Schneider Electric · Altistart 22 Soft Starter

¿Qué significa trAP ?

A low-level internal software error or exception has occurred within the soft starter's firmware. This indicates a serious internal malfunction that requires attention, often pointing to a hardware or firmware integrity issue.

Causas comunes

  • Critical internal software exception or unhandled error within the soft starter's firmware.
  • Memory access violation or data corruption in the soft starter's internal memory (e.g., RAM, flash).
  • Hardware malfunction on the control board (e.g., CPU, watchdog timer, memory chip) triggering a firmware trap.
  • Severe electromagnetic interference (EMI) causing processor instability or data corruption.
  • Corrupted firmware image due to a failed update or factory defect leading to a non-recoverable error.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Cycle power to the soft starter; wait a full 60 seconds before reapplying power for a complete system reset.

  2. 2

    2. Remove all external control wiring (digital inputs, analog inputs, communication cables) and power cycle; reintroduce wiring one by one to isolate potential external interference.

  3. 3

    3. Perform a factory reset via the soft starter keypad (e.g., setting P0-01 to 'Reset') to clear any potentially corrupted parameters or states.

  4. 4

    4. If accessible, check for proper grounding of the soft starter enclosure and ensure EMI filters are correctly installed and wired on the incoming line.

  5. 5

    5. Record the specific trap code displayed (if any) and contact manufacturer support with the code and soft starter serial number.

Ver todos los códigos en este manual (32)