Traduciendo...
dLF

Dynamic Load Error

Schneider Electric · Altivar Machine ATV320 Variable Speed Drive

¿Qué significa dLF ?

A detected error related to the dynamic characteristics of the load. This could be an unexpected change in motor load, resonance, or mechanical issues affecting the motor's operation, which the drive's control system cannot compensate for.

Causas comunes

  • Sudden changes in load inertia (e.g., coupling failure, unexpected material blockage) exceeding drive's dynamic limits.
  • Mechanical resonance in the system (e.g., motor, gearbox, driven machine) excited by specific operating frequencies.
  • Encoder or motor feedback device slip, leading to an inaccurate representation of the motor's actual speed or position.
  • Incorrectly tuned current or speed controller (e.g., Parameter P3-10 for PI gains) for the application's dynamic requirements.
  • Motor shaft or coupling breakage, causing a sudden loss of mechanical connection to the load and free-spinning motor.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Check for mechanical binding, excessive play, or damage in the motor coupling, gearbox, and driven machine.

  2. 2

    2. Observe motor current and speed actual values via the HMI during operation to identify sudden fluctuations or oscillations.

  3. 3

    3. Re-perform an autotune procedure (e.g., Parameter P0-01 = 1 for static tune, P0-01 = 3 for dynamic tune) to optimize motor control.

  4. 4

    4. Adjust the drive's acceleration/deceleration ramps (e.g., Parameter P2-01, P2-02) to soften load transitions.

  5. 5

    5. Implement a filter (e.g., Parameter P3-20 for speed filter) to damp out mechanical resonance frequencies.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Schneider Electric Altivar Machine ATV320 Variable Speed Drive