0C40

Fault in INTERBUS station (device)

SEW Eurodrive · Drives

¿Qué significa 0C40 ?

A fault has occurred in an INTERBUS station (device). The length code of the indicated MFI does not correspond with the entry in the INTERBUS configuration frame, leading to a mismatch in device identification.

Causas comunes

  • The length code set on the MFI does not match the configuration in the INTERBUS master.
  • Incorrect DIP switch setting on the MFI affecting its length code.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the DIP switch setting on the MFI to ensure it corresponds to the configured length code in the INTERBUS master.

Ver todos los códigos en este manual (39)