Oil aging/fault Display error
SEW Eurodrive · MCBSM
¿Qué significa 103 ?
The oil aging sensor signals a fault, indicating that the gear unit oil has degraded to a critical level. Continued operation with aged oil can lead to premature wear of gears and bearings, increased friction, and eventual gear unit failure.
Causas comunes
- Severe and prolonged operation beyond the oil's useful life without replacement, leading to critical viscosity loss.
- Significant thermal stress causing rapid oxidation and breakdown of the oil's additives, resulting in acid formation.
- Extensive contamination of the oil (e.g., water ingress >500 ppm), drastically reducing lubrication and protective properties.
- Mechanical wear within the gearbox generating excessive metallic particles (e.g., >100 ppm iron), accelerating oil degradation.
- Failure of the oil aging sensor itself, providing an erroneous critical fault signal (e.g., internal component failure).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
1. Immediately cease operation of the gear unit to prevent further mechanical damage.
- 2
2. Completely drain the existing aged oil from the gear unit into an appropriate waste container.
- 3
3. Flush the gearbox thoroughly with a compatible flushing oil to remove sludge and contaminants from internal surfaces.
- 4
4. Refill the gearbox with new, manufacturer-specified lubricant (e.g., ISO VG 220 synthetic gear oil) to the correct level.
- 5
5. After oil change, reset the oil aging sensor or system counter (e.g., via parameter P4-55 in the drive) and verify fault clearance.