FF0204h

Software Limit Switch CCW Exceeded

SEW Eurodrive · MOVI-PLC SyncCrane Application

¿Qué significa FF0204h ?

This fault indicates that the specified position or the actual position of an axis has moved beyond the defined counter-clockwise (CCW) software limit switch. This condition prevents further movement in the CCW direction and halts the axis system to prevent overtravel.

Causas comunes

  • Axis position exceeded the defined counter-clockwise software limit switch.
  • Encoder feedback indicates movement beyond the minimum allowed CCW position.
  • Incorrectly set CCW software limit parameter.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review and adjust the counter-clockwise software limit parameter (e.g., P5-41) to a lower value.

  2. 2

    Manually move the axis to a safe position within the limits.

  3. 3

    Check the actual encoder position reading (e.g., P5-03) to confirm it is within the new limits.

  4. 4

    Ensure the homing procedure correctly sets the initial reference position.