Traduciendo...
001C

Controller inhibit required

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 001C ?

This PROFIBUS-DP additional code (Error Class 8, 'Other Error') means an attempted parameter change requires the drive inverter to be in a 'controller inhibit' state before modification can be applied. The inverter is currently enabled, preventing the parameter change.

Causas comunes

  • A global controller inhibit signal is active, preventing operation or parameter changes.
  • An external safety or control signal is preventing modification.
  • The system requires an explicit enable command before allowing parameter updates.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.

Ver todos los códigos en este manual (78)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)