Traduciendo...
12

Resolver 14-bit

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 12 ?

Emergency stop occurs because 14-bit resolver evaluation is active, and the actual motor speed exceeds 3600 1/min. The resolver feedback system is not designed for accurate operation above this speed.

Causas comunes

  • The resolver feedback system is not providing valid or consistent positional data.
  • Faulty resolver or resolver interface board.
  • Signal interference or connection issues with the resolver wiring.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Set parameter P302 (Maximum speed 1) to a maximum value of 3600 1/min.

Ver todos los códigos en este manual (78)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)