14

Encoder Error

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 14 ?

Immediate switch-off due to an issue with the encoder feedback, such as an incorrectly connected encoder cable or shield, a short circuit or broken wire within the cable, or a defective encoder unit itself. This prevents accurate speed and position feedback.

Causas comunes

  • Encoder feedback signal is lost, corrupted, or inconsistent.
  • Faulty encoder on the motor.
  • Encoder cable disconnected or damaged, interrupting communication.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the encoder cable and shield for correct physical connection.

  2. 2

    Inspect the encoder cable for any short circuits between conductors or to ground.

  3. 3

    Inspect the encoder cable for any broken wires.

  4. 4

    If wiring is correct, replace the encoder if it is confirmed defective.