33

Setpoint Source Not Defined

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

¿Qué significa 33 ?

Immediate switch-off because the setpoint source (e.g., analog input, fieldbus, internal parameter) is either not defined or incorrectly configured. The inverter cannot determine how to receive its target values for speed, position, or torque.

Causas comunes

  • The source for setpoint commands (e.g., analog input, fieldbus) is not defined in the configuration.
  • No valid setpoint source selected in operating parameters.
  • Startup error where setpoint source is not configured before operation.
  • Invalid parameter setting for setpoint source selection.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Set the correct setpoint source using parameter P100.

Ver todos los códigos en este manual (78)