Traduciendo...
F109-150

Difference level RS485 driver. Fault Faulty "B" or "Cycle" signal

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

¿Qué significa F109-150 ?

A fault is detected in the RS485 driver, specifically with the 'B' or 'Cycle' signal. This is usually caused by no encoder connection or an incorrect encoder type being connected.

Causas comunes

  • RS485 communication line issue between driver and controller.
  • Faulty 'B' or 'Cycle' signal wire integrity.
  • Incorrect RS485 termination resistors.
  • Noise interference on the RS485 data lines.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check encoder connection.

  2. 2

    Check encoder cabling.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas