EEPROM error

SEW Eurodrive · MOVIMOT Field Distributor

¿Qué significa 25 ?

An error occurred while accessing the EEPROM (Electrically Erasable Programmable Read-Only Memory), resulting in data inconsistency. This can lead to incorrect parameter settings or loss of configuration.

Causas comunes

  • Error during EEPROM read or write operations.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Call up the factory setting "Delivery state" to restore default parameters.

  2. 2

    Perform a system reset; be aware that the IPOS program will be deleted.

  3. 3

    Set all necessary parameters again after the reset.

  4. 4

    If the fault reoccurs after these steps, contact SEW service.