Traduciendo...
C01798

Test stop for motion monitoring is running

Siemens · SINAMICS G120

¿Qué significa C01798 ?

The inverter is currently performing a forced checking procedure (test stop) for its extended motion monitoring functions. This is a normal operational state during a safety test and indicates that the system is validating its safety capabilities.

Causas comunes

  • Automatic periodic test for motion monitoring functions initiated by the safety controller.
  • Manual initiation of a safety test via HMI or safety engineering software (e.g., Startdrive).
  • System power cycle or reset triggering a safety self-test for motion monitoring.
  • Configuration change in safety parameters (e.g., P30650) requiring a verification test.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Monitor status parameter r0949 for the test progress and completion status.

  2. 2

    Confirm the status LED on the safety module (e.g., integrated safety F-CPU) indicates test activity.

  3. 3

    Wait for the test duration specified in Parameter P30650 (test interval) to complete.

  4. 4

    Verify that the motion monitoring safety function (e.g., Safe Speed Monitor) correctly re-engages after the test.

Ver todos los códigos en este manual (109)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas