58

Brake Fault

Vacon · NX All-in-One Application

¿Qué significa 58 ?

This fault occurs when the actual status of the mechanical brake does not match the drive's control signal. This mismatch indicates a problem with the brake mechanism itself or its feedback system, potentially leading to uncontrolled movement or inability to stop.

Causas comunes

  • Mechanical brake not releasing or engaging properly.
  • Brake control circuit failure or incorrect wiring.
  • Brake coil shorted or open.
  • Insufficient voltage to the brake actuator.
  • Brake position feedback signal faulty or out of range.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the mechanical state of the brake for proper engagement and disengagement.

  2. 2

    Verify all electrical connections to the brake and its feedback sensors for integrity and proper wiring.