Traduciendo...
59

Follower Communication Fault

Vacon · NX All-in-One Application

¿Qué significa 59 ?

Communication between the Master and Follower drives has been lost via SystemBus or CAN. This indicates a broken communication link, preventing coordinated operation between the units.

Causas comunes

  • Communication failure between a master and a follower drive/device.
  • Incorrect follower address or configuration (e.g., P9-01).
  • Network cabling issue between devices.
  • Follower device powered off or not initialized.
  • Data corruption during follower communication.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the option board parameters related to SystemBus or CAN communication for correct configuration (e.g., node ID, baud rate).

  2. 2

    Inspect the optical fibre cable or CAN cable for physical damage, proper connections, and correct termination between master and follower drives.

Ver todos los códigos en este manual (42)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Vacon NX All-in-One Application