F-device CRC1-Fault (V3 CPU)
ABB · PB610 Panel Builder 600 Programming Software
Hva betyr 28691 ?
A CRC1-Fault has occurred in F-device instance <n> for AC500 V3 non-safety CPU PM56xx. This indicates a data integrity error during PROFIsafe communication, suggesting corruption of safety-critical data telegrams.
Vanlige årsaker
- Cyclic Redundancy Check (CRC) error detected during F-device data transmission (CRC1).
- Data corruption during PROFIsafe communication.
- Faulty communication hardware or cable integrity issue.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the Safety PLC configuration for the F-device instance <n>.
- 2
Restart the Safety PLC module.