Encoder battery dead
ABB · Application Error ABB Motion Drives Error trouble shoo
Hva betyr 10038 ?
This informational message can appear at startup or when the drive (MotiFlex e100, MotiFlex e180, MicroFlex e190) is enabled, indicating that the battery backup supply for a Smart Abs encoder has failed or is depleted.
Vanlige årsaker
- The battery in the Smart Abs encoder has reached the end of its service life and is exhausted.
- Poor contact or corrosion at the battery terminals, preventing proper power delivery.
- The battery is missing or incorrectly installed in the Smart Abs encoder.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Replace the battery in the Smart Abs encoder with a new, compatible battery according to the encoder's specific manual and manufacturer guidelines.
- 2
Verify that the new battery is correctly installed and that its connections are secure and free from corrosion.
- 3
Check for any error messages related to the encoder after battery replacement to confirm the issue is resolved and position data is retained.
- 4
Record the battery replacement date for future maintenance planning.