223

Data cannot fit into an ICM telegram

ABB · Application Error ABB Motion Drives Error trouble shoo

Hva betyr 223 ?

The amount of data intended for transmission cannot fit into a single ICM (Internal Communication Module) telegram. This typically occurs when a host application uses `doMultipleCommands` with too many encapsulated calls.

Vanlige årsaker

  • Excessive number of encapsulated calls within a single `doMultipleCommands` instruction in the host application.
  • Attempting to transmit a data payload that exceeds the maximum size allowed for an ICM telegram.
  • Inefficient data packing or communication protocol usage within the host application.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    If using a host application with `doMultipleCommands`, reduce the number of encapsulated calls within a single command to decrease telegram size.

  2. 2

    Optimize the data transfer by splitting larger data sets into multiple smaller ICM telegrams.

  3. 3

    Review the host application's communication logic to ensure efficient use of telegram bandwidth and data packing.

  4. 4

    Consult the ICM protocol specification or drive documentation for explicit telegram size limitations.