F005

Illegal Address Format - Symbol Character Limit

Allen-Bradley · Logix and SLC PLC

Hva betyr F005 ?

This error occurs when a symbolic address or name exceeds the maximum number of characters supported by the device. The processor cannot process the overly long symbol, leading to an addressing failure.

Vanlige årsaker

  • Symbol name created with more characters than allowed by the controller's specification.
  • Attempting to use a symbol name from a different controller type with different limits.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Consult the Allen-Bradley Logix/SLC documentation for the specific PLC model to determine the maximum allowed character limit for symbolic addresses and tag names.

  2. 2

    Access the PLC program using the appropriate software (e.g., Studio 5000 Logix Designer, RSLogix 500).

  3. 3

    Inspect all recently added or modified symbolic addresses and tag names within the program for compliance with the documented character limit.

  4. 4

    Identify and Modify any symbolic address or tag name that exceeds the maximum character limit to ensure adherence to the device's specifications.

  5. 5

    Re-download the corrected PLC program to the controller and Verify the error F005 is cleared.