Torque Prove Speed Band
Allen-Bradley · PowerFlex 700
Hva betyr 20 ?
The difference between the [Commanded Speed] and [Encoder Speed] has exceeded the level set in [Spd Dev Band] for a time period greater than [Spd Band Integrat]. This indicates that the motor is not following the speed command accurately, likely due to a mechanical issue or encoder problem.
Vanlige årsaker
- Actual motor speed deviates significantly from the commanded speed band.
- Encoder feedback inaccurate or missing.
- Controller unable to maintain target speed.
- Excessive mechanical load causing speed drop.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the wiring between the drive and the motor for loose connections or damage.
- 2
Check for proper release and operation of the mechanical brake.