63

Shear Pin

Allen-Bradley · PowerFlex 700

Hva betyr 63 ?

The programmed [Current Lmt Val] has been exceeded. This indicates that the motor load has caused the drive output current to surpass a set limit, often used to protect mechanical components like a shear pin. This fault can be enabled/disabled with [Fault Config 1].

Vanlige årsaker

  • Mechanical overload causing the shear pin to break.
  • Foreign object obstruction in moving parts.
  • Excessive torque applied to the driven component.
  • Incorrect shear pin rating for the application.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the load requirements on the motor.

  2. 2

    Check the setting of the [Current Lmt Val] parameter.